CBKBT - GENETRON MP39
- MSDS: CBKBT
- Manufacturer: ALLIED SIGNAL INC
- Product Name: GENETRON MP39
- National Stock Number: 6830-00N069206
Product Identification
Product ID:GENETRON MP39
MSDS Date:05/01/1993
FSC:6830
NIIN:00N069206
MSDS Number: CBKBT
Responsible Party
US
Emergency Phone: 201-455-2000
Info Phone: 201-455-4157
Cage: 0B7T5
Contractor
Telephone: 201-455-2000/800-707-4555
Cage: 0B7T5
Ingredients
METHANE, CHLORODIFLUORO-; (CHLORODIFLUOROMETHANE) (SARA
CAS: 75-45-6
RTECS: PA6390000
Fraction By Weight: 52%
OSHA PEL 1000 PPM
ACGIH TLV: 1000 PPM
ETHANE, 1,1-DIFLUORO-; (C*2H*4F*2) (GENETRON 152A)
CAS: 75-37-6
RTECS: KI1410000
Fraction By Weight: 15%
OSHA PEL N/K
ACGIH TLV: N/K
ETHANE, 1-CHLORO-1,1,2,2-TETRAFLUORO-;
CAS: 354-25-6
RTECS: KH7985000
Fraction By Weight: 33%
OSHA PEL N/K
ACGIH TLV: N/K
PRODS. AVOID MIXING W/AIR OR OXYG ABOVE
RTECS: 9999999ZZ
EXOTHERMIC REACTION). CHEMICALLY ACTIVE
RTECS: 9999999ZZ
MAGNESIUM AND ZINC.
RTECS: 9999999ZZ
THESE ARE TOXIC AND CORROSIVE.
RTECS: 9999999ZZ
THIS MIX ARE HVR/AIR & MAY CONC NEAR FLOOR
RTECS: 9999999ZZ
WOULD RSLT FROM RAPID EVAP (PERHAPS BOILING) OF MATL,
RTECS: 9999999ZZ
IRRIT WOULD RSLT
RTECS: 9999999ZZ
INTENTIONAL MISUSE/OVEREXP MAY
RTECS: 9999999ZZ
WEAK TERATOGEN TO RATS AT A CONC OF 50,000 PPM (5%).
RTECS: 9999999ZZ
IT MAY CAUSE DISCOMFORT DUE TO ITS
RTECS: 9999999ZZ
TO DO SO BY A PHYSICIAN.
RTECS: 9999999ZZ
FOLLOW STD SFTY PREC FOR HNDLG & USE OF CYLS OF
RTECS: 9999999ZZ
OF LOW FIRE RISK. PROTECT CNTNR & ITS FITTINGS FROM
RTECS: 9999999ZZ
AVOIDED. CLOSE VALVE TIGHTLY AFTER USE & WHEN EMPTY.
RTECS: 9999999ZZ
OR OTHER PERSONAL INJURY IF NOT HNDLD PROPERLY. TANK
RTECS: 9999999ZZ
BASED ON RECOGNIZED SFTY PRINCIPLES. REF.(1). TANKS
RTECS: 9999999ZZ
PROD. OBSERVE ALL LABELED PRECAUTIONS.
RTECS: 9999999ZZ
OPERATING AND STORAGE AREAS.
RTECS: 9999999ZZ
WASHED BEFORE REUSE.
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROFLUOROCARBON (CFC) MATERIALS
HAVE PRODUCED SENSITIZATION OF THE MYOCARDIUM TO EPINEPHRINE IN
LABORATORY ANIMALS AND COULD HAVE A SIMILAR EFFECT IN HUMANS.
ADRENOMIMETICS (I.E., EPINEPHRINE) MAY BE CONTRA-INDICATED EXCEPT
FOR LIFE-SUSTAINING USES IN HUMANS ACUTELY OR CHRONICALLY EXPOSED
TO CFCS. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:ACUTE:ING 3 IS STILL BEING TESTED.
RSLTS TO DATE INDICATE LOW ORDER OF TOX IN ANIMAL TESTS UP TO 3
MONTHS. INGS 1 & 2 ARE ALSO LOW ORDER OF TOX IN TESTS UP TO 2
YEARS. CARE NEEDS TO BE TAKEN TO MAINTAIN EXPOS @ OR BELOW REC LEV
TOAVOID DEPRESS OF CNS. THESE TRANSIENT EFTS MAY REDUCE ALERTNESS.
VAPS OF (ING 8)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:INHAL:IMMED REMOVE TO FRESH AIR. IF BRTHG HAS STOPPED, GIVE
ARTF RESP. USE OXYG AS REQD, PROVIDED QUALIFIED OPERATOR IS AVAIL.
CALL PHYS. DO NOT GIVE EPINEPHRINE (ADRENALINE). EYES:IMMED FLUSH
W/LG AM TS OF WATER FOR @ LEAST 15 MINS, LIFTING EYELIDS OCCASNLY
TO FACILITATE IRRIGATION. GET MED ATTN. SKIN:PROMPTLY FLUSH W/WATER
UNTIL ALL CHEM IS REMOVED. GET MED ATTN IF IRRIT IS PRESENT. (ING
13)
Fire Fighting
Flash Point:WILL NOT BURN
Extinguishing Media:USE ANY STANDARD AGENT-CHOOSE ONE MOST APPROP FOR
TYPE OF SURROUNDING FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESS DEMAND SCBA &
FULL PROT EQUIP . PROPER EYE & SKIN PROT SHOULD BE PROVIDED. USE
WATER SPRAY TO KEEP FIRE-EXPOS CNTNRS (SUPDAT)
Unusual Fire/Explosion Hazard:THERM DECOMP PRODS MAY INCL FLUORIDES,
CHLORIDES, & PHOSGENE . MIX IS NOT FLAM. ING 2 DOES HAVE FLAME LIMS
& ING 1 IS COMBUST WHEN MIXED W/AIR @ (SUPDAT)
Accidental Release
Spill Release Procedures:(ALWAYS WEAR PERSONAL PROT EQUIP):EVAC ALL
UNPROTECTED PERS. PROTECTED PERS SHOULD REMOVE ANY FLAMES & SHUT
OFF LEAK, IF W/OUT RISK, & PROVIDE VENT. UNPROTECTED PERS SHOULD
NOT RETURN UNTIL AIR HAS BE EN TESTED & DETERM SAFE, INCL
LOW-LYINGAREAS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID BRTHG VAPS/LIQ CONT W/EYES, SKIN
OR CLTHG. DO NOT PUNCTURE/DROP CYLS/EXPOSE THEM TO OPEN
FLAME/EXCESS HEAT. USE AUTHORIZED CNTNRS ONLY.(ING 15)
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE THE FORMATION OF CHLORIDES, FLUORIDES OR
PHOSGEN .
Exposure Controls
Respiratory Protection:NONE GENERALLY REQD FOR ADEQ VENTILATED WORK
SITUATIONS. FOR ACCIDENTAL/NON-VENTILATED SITUATIONS, USE
NIOSH/MSHA APPRVD SCBA OR NIOSH/MSHA APPRVD SUPPLIED AIR
RESPIRATOR.
Ventilation:PROVIDE LOC EXHAUST @ FILLING ZONES & AREAS WHERE LEAKAGE
IS PROBABLE. MECH (GEN) VENT MAY BE ADEQ FOR OTHER (ING 21)
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPRVD CHEM WORK GOGGLES .
Other Protective Equipment:IMPERVIOUS BOOTS. ANSI APPRVD EMER EYE WASH
& DELUGE SHOWER .
Work Hygienic Practices:REMOVE & WASH CLTHG PROMPTLY, IF WET. ANY
NONIMPERVIOUS CLTHG SHOULD ALSO BE PROMPTLY REMOVED WHEN CONTAMD &
(ING 22)
Supplemental Safety and Health
VP:111.2 PSIA @ 77F. FIRE FIGHT PROC:COOL & TO SUPPRESS VAPS. FIRE
EXPLO:PRESS ABOVE ATM. ING 3, BY ANALOGY, IS EXPECTED TO EXHIBIT
SIMILAR CHARACT TO ING 1. IT IS THEREFORE, REC THAT AIR NOT BE
MIXED W/MP-39 @ PRESS EXCEEDING ATM & THAT MIX OF AIR & MP-39 NOT
BE USED FOR LEAK DETECTION.
Chemical Properties
Boiling Pt:B.P. Text:-27F,-33C
Vapor Pres:SUPDAT
Vapor Density:1.188
Evaporation Rate & Reference:>1 (CCL=1)
Solubility in Water:24 WT % @ 25C(77F)
Appearance and Odor:LIQUEFIED GAS, SLIGHT ETHEREAL.
Percent Volatiles by Volume:100 WT
Stability
Stability Indicator/Materials to Avoid:YES
(UNDER SPECIFIC CNDTNS:E.G., VERY HIGH TEMPS &/OR APPROP PRESS).
FRESHLY ABRADED ALUMINUM SURF(MAY CAUSE STRONG (ING 5)
Stability Condition to Avoid:ANY SOURCE OF IGNIT SUCH AS LIGHTED
CIGARETTES, FLAMES, HOT SPOTS, WELDING. MAY YIELD TOX &/OR CORR
DECOMP (ING 4)
Hazardous Decomposition Products:CHLORIDES, FLUORIDES & PHOSGENE .
HALOGENS, HALOGEN ACIDS, & POSSIBLY CARBONYL HALIDES SUCH AS
PHOSGENE. (ING 7)
Disposal
Waste Disposal Methods:DISP OF WASTE MP-39 MAY BE SUBJECT TO FED, STATE
& LOC REGS. USERS SHOULD REVIEW THEIR OPERATIONS, THEN CONSULT
W/APPROP REGULATORY AGENCIES BEFORE DISCHARGING/DISPOSING OF WASTE
MATL. DISP BY LICENSE D WASTE DISP COMPANY MAY BE NECESSARY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.